Error description 237-1301D
Error message
1301D UM: logical disturbance of data reception CC%2 %1, error code=%4
Cause of error
The communication component for the optical fiber connection (HFL) to the inverters reports an error
Possible causes:
- Hardware defective
- Electromagnetic disturbances
- Optical fibers (HFL) not connected correctly
- Insufficient bend radius of the optical fibers (HFL)
Error correction
- Create a service file (error code gives information about the exact cause of the error for the diagnosis at HEIDENHAIN)
- Inform your service agency
- If required, exchange the hardware
- Use TNCdiag to check the damping of the fiber-optic connections (HFL). If the damping is too high:
- Check the optical fiber connections
- Comply with the guidelines in the Technical Manual regarding the cable routing
- Check the machine for correct shield connections and grounding
- Check the motor and power cables for correct shield connections and terminal connections